Model LTN-3R
(550VA - 1.3kVA)
Description:
Shouldn’t the UPS technology be as rugged as the outdoor-rated enclosure in which it’s provided?
Many of today’s “outdoor UPS systems” are simply a commercial grade standby power supply in an outdoor-rated enclosure. These designs offer no real power line conditioning, isolation, or meaningful voltage regulation. Many offer only ±10% voltage regulation and have a 5 millisecond break in power when transferring to or from battery backup.
Why settle for this performance when our Model LTN-3R offers so much more?
Within each Model LTN-3R UPS is a rugged constant voltage transformer which provides output line voltage regulation of ±3%. In addition, magnetic isolation, filtering, and power conditioning provide ultimate protection from extreme power line disturbances and power outages. A free-standing outdoor UPS, the Model LTN-3R may be floor- or pad-mounted at its installation site.
Single Phase Sizes: 550 VA, 1 kVA, 1.3 kVA
Output Power Rating: kVA at 1.0 power factor (unity), kVA = kW
- No break, regulated, continuous sine wave output.
- Integral constant voltage transformer isolates and regulates output voltage.
- NEMA 3R rain-tight enclosure design.
- Internal status and alarm panel, with optional viewing window.
- Internal battery options, providing extended runtimes from 30 minutes to 9.5 hours at full load, model dependent.
- Input and output main circuit breakers.
- Make-before-break maintenance bypass switch.
- Standard 8.5 amp accelerated, temperature-compensated battery charger.
- Elastomeric insulation prevents condensation and internal moisture.
- Conformal coated circuit boards.
- Keyed door latches.
- Front-access design.
- Generator compatible.
- Remote communications via alarm signals or RS232.
- Optional heater and related thermostat.
- Optional remote monitoring via Ethernet TCP/IP.
- Input Operating Voltage Range: +10%, -40% typical, load-dependent, without battery usage
- Input Frequency: 60 Hz, ±2.5 Hz
- Output Power Rating: kVA at 1.0 power factor (unity), kVA = kW
- Output Sine wave Voltage: Maximum 3% harmonic distortion, any single harmonic
- Voltage Regulation: ± 3% typical
- Isolation: Galvanic
- Operating Temperature: -35° C to +55° C (-31° F to 131° F)
- Total System MTBF: 100,000 hours
- Common Mode Noise Attenuation: 120 dB
- Transverse Mode Noise Attenuation: 70 dB
- Efficiency: 89% typical
- Security Systems/Surveillance Cameras
- Parking Garage Kiosks/Gate Arms
- Motor Drives For Barrier Control
- Highway Tollgates
- Vehicle/Cargo Scanning
- Traffic Signal Controls
- Pumps/Controls/Telemetry
- Irrigation Systems
- Transmission Repeaters/Cell Towers
- Radio/TV Transmitter Sites
- Solar Array Controls
Learn more about this product! Read our brochures and other supporting documents!
- Can the Model LTN-3R operate in high temperature, wind, rain, sleet, and snowy conditions?
- How does the Model LTN-3R regulate voltage?
- Does the Model LTN-3R do anything to correct for load generated harmonics?
- Does the Model LTN-3R preserve the battery life in harsh temperature conditions more than other UPS models?
- Can I perform maintenance on the Model LTN-3R UPS without disrupting power to my equipment?
Controlled Power Company warrants the Model LTN-3R Uninterruptible Power System to be free from defects in material and workmanship for a period of one (1) year following shipment from the factory. Batteries are warranted with a one (1) year full replacement warranty, and an optional four (4) year pro-rate with applicable maintenance contract. Controlled Power Company agrees to replace, F.O.B. its factory, any parts which fault through defect in material or workmanship during the warranty period.
Warranty begins from date of shipment unless a factory start-up is purchased, then the warranty begins from date of start-up or 90 days from ship date; whichever comes first.
Consult the factory for additional warranty details, and a description of start-up services provided.