Series 800A Commercial Power Purifier
(1kVA - 15kVA)
Description:
The Series 800A Commercial Power Purifier is a self-regulating, constant voltage transformer. It provides isolation and protects against fluctuating voltage, brownouts, line noise and short duration power outages. Because of the Commercial Power Purifier’s power conditioning properties, it also attenuates voltage spikes and provides a unique power “ride through” capability. With loss of input power for up to one cycle, the output sine wave remains at usable AC voltage levels! The Commercial Power Purifier is provided in a NEMA1 enclosure and is ideal for power quality problems found in commercial facilities.
Single Phase Sizes: 1.0kVA, 1.6kVA, 2.1kVA, 2.5kVA, 3.5kVA, 5.0kVA, 7.5kVA, 10kVA, 15kVA
- State-of-the-art constant voltage transformer protects sensitive electronic equipment against all power line disturbances, line noise, and transients
- Provides “ride-through” capability for up to (1) full cycle
- Acts as a large filter to reduce reflected harmonics
- Solves most power related problems, thereby protecting and enhancing the performance of critical equipment
- Variable Range Regulation (VRR) – Input operating voltage range increases as an inverse function of load
- Tight output voltage regulation
- Standard input plug with 8 ft. line cord on models up to 3.5kVA
- Standard (4) 5-20R or 5-15R output receptacles on models up to 3.5kVA; optional receptacles on models from 3.5kVA to 15kVA
- Hospital-grade 15 amp or 20 amp input plug and output receptacles are available upon request
- Input Operating Voltage Range: +10%, -20% at full load; down to -40% from nominal at 50% load
- Output Voltage Regulation: ± 3% from nominal
- Load Regulation: 3-4% from 0% to 100% load
- Input Current THD: <5%
- Common Mode Noise Attenuation: 140dB
- Transverse Mode Noise Attenuation: 120dB
- Operating Temperature: -20°C to +40°C
- Efficiency: 90% typical
- Leakage current to ground: Less than or equal to 20 microamps (1 kVA – 3.5 kVA)
- Safety Listing: UL 1012
- High-End Digital Photography
- Communications
- Computing
- Security Systems
- Data Acquisition
- Test and Measurement Instrumentation
- Sensitive Electronic Equipment
- Medical Labs
Learn more about this product! Read our brochures and other supporting documents!
- Is the ferroresonant technology an old or outdated technology?
- Are all tap switching power conditioners the same?
- Is it true that ferroresonant transformers must be partially loaded to function correctly?
- Is it true that the MTBF is 200,000 hours?
- Just what is VRR?
- Does the Commercial Power Purifier really correct power factor and attenuate harmonics?
- Will the Commercial Power Purifier handle a short circuit?
- Can the Commercial Power Purifier be used in medical applications?
Controlled Power Company warrants the Series 800A Commercial Power Purifier to be free from defects in material and workmanship for a period of 10 years on the transformer (core and coil), and 2 years on all other unit components. Controlled Power Company agrees to replace, F.O.B. its factory, any parts which fault through defect in material or workmanship during the warranty period.
Warranty begins from date of shipment unless a factory start-up is purchased, then the warranty begins from date of start-up or 90 days from ship date; whichever comes first.
Consult the factory for additional warranty details, and a description of start-up services provided.