eLITE Model ELE
(5.3kW-18kW)
Description:
The eLITE Model ELE is a modular, no-break, front access, single phase centralized emergency lighting inverter that provides conditioned and regulated power to normally on and normally off fixtures. The Model ELE is listed to “UL 924 Emergency Lighting Equipment,” “UL 924 Auxiliary Lighting and Power Equipment,” and “UL 1778 Uninterruptible Power Supplies” standards. The Model ELE is also compliant with NFPA 101 and NFPA 111 requirements for testing of emergency lighting inverter systems.
The Model ELE is compatible with LED drivers/fixtures, and is a perfect choice when a larger kW-rated single phase emergency power source is required . . . up to and including 18kW!
Single Phase Sizes: 5.3kW, 7.5kW, 8.5kW, 10kW, 12.5kW, 14.5kW, 16kW, 18kW
- Automatic self-testing, data logging, and reporting per NFPA 101 – 7.9.3.1.3.
- Uninterrupted, regulated, continuous sine wave output for use with “normally on” lighting fixtures and exit lamps
- True no-break system, providing voltage regulation and performance characteristics that extend ballast, LED driver, and lamp life
- Standby output for use with “Normally Off” lighting fixtures
- Front access, modular cabinet construction
- Integral constant voltage transformer isolates and regulates output voltage
- Delivers highly filtered and spike-free power to emergency lighting fixtures and “Life Safety” devices
- Overload and short-circuit proof
- Front access distribution, with lockable drop-down panel door
- Standard AC and DC input protection
- Generator compatible
- NEMA1 enclosure
- Internal make-before-break bypass switch
- Optional zone sensing
- Optional control device override (wall switch, occupancy sensor, dimmer, etc.)
- Optional CB trip indicator alarm/light
- Electrically isolated output
- Advanced monitoring system
- Optional NetMinder Ethernet/MODBUS adapter for network monitoring
- Input Operating Voltage Range: +10%, -15% without battery usage
- Input Frequency: 60 Hz, ± 2.5 Hz
- Input Current Harmonic Distortion: Less than 10%
- Power Factor: Self-correcting to > 0.95
- Output Sine wave Voltage: Maximum 3% harmonic distortion, any single harmonic
- Output Voltage Regulation: Typically better than ± 3%
- Isolation: Galvanic
- Standard Unit Operating Temperature: 0°C to 40°C
- Total System MTBF: 100,000 hours
- Common Mode Noise Rejection: 120 dB
- Transverse Mode Noise Rejection: 70 dB
- Efficiency: 90% typical
- Schools/Universities/Dormitories
- Security/Public Address Systems
- Arenas/Stadiums
- Subways/Mass Transit
- Parking Structures/Garages
- Hospitals/Clinics
- Shopping Malls
- Banks/Financial Institutions
- Airport Terminals
- Casinos/Resorts
- Hotels/Motels
- Apartment Buildings
- Prisons
Learn more about this product! Read our brochures and other supporting documents!
- What are centralized lighting inverters and why use them?
- Is the eLITE Model ELE NFPA 101 compliant?
- Does the eLITE Model ELE have a transfer time, and if so, is it important?
- Does the eLITE Model ELE extend the life of lighting fixtures?
- Is the eLITE Model ELE capable of operating both normally off and normally on lighting fixtures?
- Can the eLITE Model ELE support different types of lighting at different voltages simultaneously?
Controlled Power Company warrants the eLITE Model ELE Emergency Lighting Inverter to be free from defects in material and workmanship for a period of two (2) years following shipment from the factory. Batteries are warranted with a one (1) year full replacement, and 14 year pro-rated warranty. Controlled Power Company agrees to replace, F.O.B. its factory, any parts which fault through defect in material or workmanship during the warranty period.
Warranty begins from date of shipment unless a factory start-up is purchased, then the warranty begins from date of start-up or 90 days from ship date; whichever comes first.
Consult the factory for additional warranty details, and a description of start-up services provided.